• Technology |
Standards |
IEEE 802.3 for 10BaseT
IEEE 802.3u for 100BaseT(X) and 100BaseFX
IEEE 802.3x for Flow Control
IEEE 802.1D-2004 for Spanning Tree Protocol
IEEE 802.1w for Rapid STP
IEEE 802.1p for Class of Service
IEEE 802.1Q for VLAN Tagging |
• Software Features |
Management |
IPv4/IPv6, SNMP v1/v2c/v3, LLDP, Port Mirror, RMON, DHCP Server/Client,
DHCP Option 66/67/82, BootP, TFTP, SNTP, SMTP, RARP, Telnet, Syslog,
SNMP inform, Flow Control, Backpressure flow control |
Filter |
802.1Q, Port-Based VLAN, GVRP, IGMP v1/v2, GMRP |
Redundancy Protocols |
STP, RSTP, Turbo Ring v1/v2, Turbo Chain |
Time Management |
SNTP, NTP Server/Client |
Industrial Protocols |
EtherNet/IP, Modbus/TCP |
MIB |
MIB-II, Ethernet-Like MIB, P-BRIDGE MIB, Bridge MIB, RSTP MIB, RMON MIB
Group 1, 2, 3, 9 |
• Switch Properties |
MAC Table Size |
8 K |
Packet Buffer Size |
1 Mbit |
• Interface |
RJ45 Ports |
10/100BaseT(X) auto negotiation speed, Full/Half duplex mode, and auto
MDI/MDI-X connection |
Fiber Ports |
100BaseFX ports (SC/ST connector) |
Console Port |
RS-232 (RJ45 connector) |
DIP Switches |
Turbo Ring, Master, Coupler, Reserve |
LED Indicators |
PWR1, PWR2, FAULT, MSTR/HEAD, CPLR/TAIL, 10/100M |
Alarm Contact |
1 relay output with current carrying capacity of 1 A @ 24 VDC |
• Optical Fiber |
|
• Power Requirements |
Input Voltage |
¡Ó24/¡Ó48 VDC, redundant dual inputs (mixing power polarity systems is
prohibited) |
Operating Voltage |
-60 to -19 VDC or 19 to 60 VDC |
Input Current |
0.28 A @ 24 V |
Inrush Current |
63 A @ 24 V
82 A @ 48 V |
Overload Current Protection |
Present |
Connection |
1 removable 6-contact terminal block |
Reverse Polarity Protection |
Present |
• Physical Characteristics |
Housing |
Metal, IP30 protection |
Dimensions |
53.6 x 135 x 105 mm (2.11 x 5.31 x 4.13 in) |
Weight |
890 g |
Installation |
DIN-rail mounting, wall mounting (with optional kit) |
• Environmental Limits |
Operating Temperature |
Standard Models: 0 to 60¢XC (32 to 140¢XF)
Wide Temp. Models: -40 to 75¢XC (-40 to 167¢XF) |
Storage Temperature |
-40 to 85¢XC (-40 to 185¢XF) |
Ambient Relative Humidity |
5 to 95% (non-condensing) |
• Standards and Certifications |
Safety |
UL 508 |
EMC |
EN 55032 Class A |
EMI |
CISPR 32, FCC Part 15B Class A |
EMS |
IEC 61000-4-2 ESD: Contact: 6 kV; Air: 8 kV
IEC 61000-4-3 RS: 80 MHz to 1 GHz: 10 V/m
IEC 61000-4-4 EFT: Power: 4 kV; Signal: 2 kV
IEC 61000-4-5 Surge: Power: 2 kV; Signal: 2 kV
IEC 61000-4-6 CS: 10 V
IEC 61000-4-8 |
Shock |
IEC 60068-2-27 |
Freefall |
IEC 60068-2-32 |
Vibration |
IEC 60068-2-6
¡@ |
• MTBF (mean time between
failures) |
Time |
363,000 hrs |
Standard |
Telcordia (Bellcore), GB |
• Warranty |
Warranty Period |
5 years |
Details |