ServerBank ¤O±ô¸ê°TServerBank¸ê°T±ÄÁʺô >
ºô¸ô³]³Æ/ÀW¼eºÞ²z
|
|
|
¡@ |
Powerful
In desktop switching environments, wire-speed
performance with full QoS control for all 10/100
interfaces is critical. The 2 Gigabit Ethernet
combo interfaces provide unprecedented
flexibility, whether you are stacking between
switches, attaching bandwidth-thirsty file
servers, or aggregating critical data to the
core of your network.
Easy-to-use
Simplify and reduce IT staff workload and
mean time to repair with intuitive, GUI-based
device configuration, and an industry-standard
command-line interface (CLI). New 2.5 Gbps,
high-speed stacking capabilities allow you to
build a single IP manageable device with up to
eight switches.
Outstanding Value
With their high-value price point, flexible
design, and reduced maintenance requirements,
NETGEARs ProSafe 10/100 Layer 2+ Stackable
Switch solutions yield a high return on
investment, and are ideal for delivering highly
reliable, converged voice, video, and data
services over a single network infrastructure.
Work Space Friendly
The switch has a built-in thermal sensor to
automatically speed up the fan to increase air
flow in warm environments, and slow down the fan
to reduce the noise when operating in an office
environment.
Customer Testimonials
"The new Netgear ProSafe Layer 2 managed
switches, FSM726E, FSM7226RS & FSM7250RS, bring
users an excellent rich feature set coupled with
a very intuitive and easy to use GUI for those
who arent quite so familiar with the use of the
command line for managing a switch.
Additionally, with Netgear¡¦s usual attention to
detail and extensive and stringent beta testing
procedures, this is a product that you can be
assured provide you with stability and
reliability. For this reason alone, we use
Netgear products as our manufacturer of choice
for all of our client installations as we can
rest assured that this will provide them with
both a reliable platform and reduce their need
for support from us."
Chris Hemmings
Managing Director
Penguin Internet Ltd
http://www.penguin-uk.com/
|
NETGEAR L2 MANAGED STACKABLE SWITCH WITH STATIC ROUTES -FSM7226RS - ServerBank¸ê°T±ÄÁʺô FSM7226RS ºô¸ô³]³Æ/ÀW¼eºÞ²z
¡@
Network Protocol and Standards
Compatibility
- IEEE 802.3 10BASE-T
- IEEE 802.3u 100BASE-TX
- IEEE 802.3z 1000BASE-X
- IEEE 802.3ab 1000BASE-T
- IEEE 802.3x flow control
Layer 2 Services
- IEEE 802.1Q static VLAN (up to
512)
- IEEE 802.1p Class of Service
(CoS)
- IEEE 802.1D Spanning Tree
Protocol
- IEEE 802.1v protocol VLAN & port
VLAN
- IEEE 802.1w Rapid Spanning Tree
Protocol
- IEEE 802.1s Multiple Spanning
Tree Protocol
- IEEE 802.3ad link aggregation
(Static, LACP)
- IEEE 802.1x port access
authentication
- Mac-based VLAN
- IGMP v1, v2, v3 snooping support
- IGMP querier
- Network storm protection,
including broadcast, multicast and
unicast traffic
- Static multicast filtering
- Ingress rate limit in 1Kbps
increments
- Protected port
- Private group VLAN
- Double VLAN
- MAC filter
- Port security
Layer 3 Services
- VLAN routing
- Static routing
- Port-based routing
- Access Control Lists - MAC, IP,
TCP
- ACLs - 224 global rules
- DiffServ QoS (RFC 2998)
- DNS caching
- DHCP/BOOTP relay - primary and
backup (RFC3046, option 82)
- UDP relay
Switch Management Specifications
- SNMP v1, v2c, v3 with multiple
IP addresses
- RFC 1157, 1901-1910, 2574, 2575
- RFC 768 UDP
- UDP relay
- RFC 854-859 telnet
- RFC 951 BOOTP
- RFC 1027 Proxy ARP
- RFC 1213 MIB II
- RFC 1757 RMON groups 1,2,3, and
9
- RFC 1215 SNMP traps
- RFC 1493 bridge MIB
- RFC 1643 Ethernet interface MIB
- RFC 1534 DHCP and BOOTP
interoperation
- RFC 2030 Simple Network Time
Protocol (SNTP)
- RFC 2131, 2132 DHCP and BOOTP
- RFC 2865 RADIUS (both switch and
management access)
- RFC 2866 RADIUS accounting
- Private enterprise MIB
- CPU traffic monitor
- Port mirroring support
(many-to-one)
- SYSLOG
- Firmware upgrade via TFTP or
HTTP
- Port description
- TACACS+
- LLDP/LLDP-MED
- DHCP server
- DHCP option 81
Single IP Address Management
(firmware version 7.3 or higher)
- Manage up to 48 fully managed
switched
- Feature can be used with the
following models:
- FSM726E, FSM7226RS,
FSM7250RS
- FSM7328S, FSM7352S,
FSM7328PS, FSM7352PS
- GSM7224R, GSM7248R
- GSM7328S, GSM7328FS,
GSM7352S
User Interfaces
- Command-line interface (CLI) via
console port
- Prosafe Control Center Web-based
management via embedded HTTP server
protected with Secured Sockets Layer
(HTTPS)
- (SSLv3) or Transport Layer
Security (TLS v1)
- Telnet remote login (5 sessions)
securable with Secure Shell (SSH
v1.5, v2)
LEDs
- Per port: Speed, link, activity
- Per device: Power, fan status,
stack ID, master, RPS
Physical Interfaces
- 24 (FSM7226RS) or 48 (FSM7250RS)
RJ-45 connectors for 10BASE-T,
100BASE-X (Auto Uplink and auto
negotiate on all ports)
- 2 1000Base-X with optional SFP
connectors for fiber connection
- 2 stacking ports at 2.5 Gbps
each
- RS-232 console port
Performance Specifications
- Forwarding modes: Store and
forward
- Bandwidth:
- FSM7226RS: 18.8 Gbps; 6.5
Mpps
- FSM7250RS: 23.6 Gbps; 10.1
Mpps
- Switch latency: Less than 80
microseconds for 64-byte frames
- System memory: 128 MB
- Packet buffer memory: 1 MB
- Code storage (flash): 32 MB
- MAC addresses size: 8K
- Number of VLANs: 512 (1-4093 ID)
- Number of trunks: 24
- Number of QoS queues: 8
- Number of static routes: 32
- Jumbo frame support: up to 9K
packet size
- Number of multicast groups: 256
Electrical Specifications
- Power consumption:
- FSM7226RS - 15W
- FSM7250RS - 33W
- 100-240V AC/50-60 Hz universal
input
- External RPS unit (12V)
Physical Specifications
- FSM7226RS
- Dimensions (w x d x h):
440 x 205 x 43 mm
(17.32 x 8.1 x 1.7 in)
- Weight: 2.8 kg (6.2 lb)
- Acoustic noise:
(ANSI-S10.12) 36.6 dB
- Heat dissipation: 51 Btu/hr
- Mean time between failures (MTBF):
562,110 hours (~64 years)
- Thermal sensor
- FSM7250RS
- Dimensions (w x d x h):
440 x 257 x 43 mm
(17.32 x 10.1 x 1.7 in)
- Weight: 3.6 kg (7.9 lb)
- Acoustic noise:
(ANSI-S10.12) 38.3 dB
- Heat dissipation: 112 Btu/hr
- Mean time between failures
(MTBF):
385,102 hours (~44 years)
- Thermal sensor
Environmental Specifications
- Operating temperature: -5¢X to
50¢X C (23¢X to 131¢X F)
- Storage temperature: -20¢X to 70¢X
C (-4¢X to 158¢X F)
- Operating humidity: 90% maximum
relative humidity, non-condensing
- Storage humidity: 95% maximum
relative humidity, non-condensing
- Operating altitude: 10,000 ft
(3,000 m) maximum
- Storage altitude: 10,000 ft
(3,000 m) maximum
Electromagnetic Emissions
- CE mark, commercial
- FCC Part 15 Class A
- VCCI Class A
- EN 55022 (CISPR 22), Class A
- C-Tick
Electromagnetic Immunity
Safety
- CE mark, commercial
- CSA certified (CSA 22.2 #950)
- UL listed (UL 1950)
- CUL IEC 950
- EN 60950
Warranty
- NETGEAR Lifetime Warranty†
Package Contents
- ProSafe L2+ Managed Switch
(FSM7226RS or FSM7250RS)
- Power cable
- Null modem cable
- Stack cable
- Rubber footpads for tabletop
installation
- Rack-mount kit
- Quick Installation guide
- Resource CD-ROM with user manual
- ProSafe NMS100 30-Day Trial
CD-ROM
- Warranty/support information
card
NETGEAR Related Products
- 1000BASE-SX SFP GBIC (AGM731F)
- 1000BASE-LX SPF GBIC (AGM732F)
- 1000BASE-ZX SFP GBIC (AGM733)
- NMS100 Network Management
Software
ProSupport Service Packs Available
- FSM7226RS
- OnCall 24x7, Category 1
- PMB0331-100 (US)
- PMB0331 (non-US)
- XPressHW, Category 1
- FSM7250RS
- OnCall 24x7, Category 2
- XPressHW, Category 2
Ordering Information
- FSM7226RS
- North America:
FSM7226RS-100NAS
- Europe: FSM7226RS-100EUS
- Asia: FSM7226RS-100AJS
- FSM7250RS
- North America:
FSM7250RS-100NAS
- Europe: FSM7250RS-100EUS
- Asia: FSM7250RS-100AJS
¡@ |
|
¡D¥»¤å¥óªº¸ê°TY¦³×§ï¡A®¤¤£¥t¦æ³qª¾¡C
¡D³W®æ©Î³ø»ùY¦³»~¡A¥Hì¼t«¬¿ý©Î¥¿¦¡³ø»ù³æ¬°¥D¡C
¡D¥»ºô¯¸¤º®e©Î¤å¥ó·í¤¤©Ò´£¤Î¤§«~µP¤Î²£«~¦WºÙ©Î¹Ï¤ù§¡¬°¨äì©ÒÄݤ½¥q¤§ª©Åv¡B°Ó¼Ð©Îµù¥U°Ó¼Ð¡C
º¡¤@©w¼Æ¶q©Îª÷ÃBÁÙ¦³¦h´ÚÃØ«~¥i¨Ñ¿ï¾Ü³á!
ServerBank ¤O±ô¸ê°Tµ¹§A³Ì¶WÈÀu´fªºNETGEAR - FSM7226RS - ºô¸ô³]³Æ/ÀW¼eºÞ²z
,³Ì¦nªºNETGEAR - L2 MANAGED STACKABLE SWITCH WITH STATIC ROUTES -FSM7226RS±ÄÁÊ¿ï¾Ü´N¦b ServerBank!
|
¥æ©ö¤è¦¡¡G
±z¤£½T©w¥H¤W°Ó«~¬O§_²Å¦X±zªº»Ý¨D?¨SÃö«Y¡A§ÚÌ·|¬°±z¦Vì¼t½T»{¡C©Î¬O±z§Æ±æ¼W´î¥H¤W°Ó«~¤§³W®æ¹s²Õ¥ó¡A§Ú̳£¥i¼u©Ê°t¦X±zªº»Ýn³ø»ù¤Î¥X³f¡C ¦p±z¹ï¥H¤W²£«~³W®æ¥H¤Î»ù®æº¡·N¡A¥i³z¹L¥H¤U¤è¦¡¶i¦æ±ÄÁÊ¡G
1.¹q¸ÜÁpô¡G ½Ðª½±µ¨Ó¹q¡G(02)8969-0901 |
2.ºô¸ô¸ß»ù¡GÂI¿ï¥»¶ÁʶR¸ß»ù§ÚÌ·|¥ß§Y»P±zÁpô! |
3.¨Ó¨ç¸ß»ùEmail: service@serverbank.com.tw |
|
¥I´Ú¤è¦¡¡G¦p«È¤á¬°º¦¸¥æ©ö±Ä²{ª÷¥æ©ö¡C |
¶Ç¯uq³æ¡G ª½±µ±N¥¿¦¡³ø»ù³æñ¦W«á¶Ç¯u¦Ü(02)2253-9016 §Y§¹¦¨qÁʵ{§Ç¡A§ÚÌ·|©ó³Ìµu®É¶¡¤º¹q¸Ü½T»{q³æ¡C |
±H°e®É¶¡¡G¨Ì³y¤£¦P¼tµP¥N²z°Ó¦³©Ò¤£¦P¡A¤j¦h¼Æ°Ó«~©ó 7 Ó¤u§@¤Ñ¯à°e©è«È¤áºÝ¡A§Ú̦¬¨ì±zq³æ®É·|¦P®É¦^Âбz½T©w¥æ´Á¡C |
°e³f¤è¦¡¡G(1) ì¼t©Î¬O¥N²z°Óª½±µ°t°e (2) ¥ÑServerBank©e°U¦v°t©Î¬O³f¹B¤½¥q°e¹F¡C |
°e³f½d³ò¡G¥xÆW¥»®q¦a°Ï¡A¹B¶O¥Ñ ServerBank ¬°±zt¾á¡Aª`·N¡I¦¬¥ó¦a§}½Ð¤Å¬°¶l¬F«H½c¡C |
°â«áªA°È¡GY²£«~¥»¨·å²«©Î¹B°e¹Lµ{¾ÉP·s«~·å²«¡A¨ì³f7¤é¤º¥i§ó´«·s«~¡C |
«O©T¬Fµ¦¡G ¹ê»Ú¥Hì¼t¤Î¥N²z°Ó¤½§i«O©T±ø¥ó¬°¥D¡A¬d¾\Áʪ«»¡©ú»P«O©TªA°È¡C |
¤O±ô¸ê°T ServerBank Inc. ²¤¶
¥Ø«e¤w¸g¬°¶W¹L30000®a¥ø·~´£¨ÑIT¸ê°T¬[ºc©Ò»Ýªº³nµwÅé³]³Æ¡A¦U¦æ·~ª¾¦W«È¤á¦p¡G
»s³y·~¡G¥x¿n¹q¡B¤Í¹F¡BÂE®üºë±K¡B¤O´¹¥b¾ÉÅé¡B¦w±¶Û¡B¥xÆWªFªÛ¡B¥xÆW^¸â¡B¥¿´Q¡B§¡»¨¡B§»¥¿¡B©MºÓÁp¦X¡BªF¶©¡B«Ø¿³¹q¤l¡B¸§Q®ú©úùÖ¡B®õª÷Ä_¡B¯«³q¡B¯«¹F¡B°¶³Ð¤O¡B±d¥þ¡B°ê²³¡B±á¬P¥b¾ÉÅé¡B¼s¹F¹q¸£¡B¼s¿o¹q³q¡BÁpµØ®ðÅé¡BÄ_¦¨¤u·~¡B¼s¹B¡B
¥~°Ó¡G ¥xÆWNTT¡B¥xÆW·Nªk¥b¾ÉÅé¡B¥xÆWNEW Balance¡B¥xÆWNEC¡B¥xÆWSONY¡B¥xÆW´I¤h¥þ¸S¡B
ª÷¿Ä¡G°ê®õ¤H¹Ø¡B¤¸¤jÃÒ¨é¡B«n¤s¤H¹Ø¡B°ê®õ¥@µØ¡B¥xÆW¤u·~»È¦æ¡B¥xÆWª÷¿Ä¬ã°V°|¡B¤T°Ó¬ü¨¹¤H¹Ø¡B¤j¸Û«OÀI¡Bªk°ê¤Ú¾¤¤H¹Ø¡B«O¸Û¤H¹Ø¡B°êµØ¤H¹Ø¡B²Î¤@ÃÒ¨é¡B´I¨¹¤H¹Ø¡BµØ«n²£ª««OÀI¡B·s¥ú¤H¹Ø¡B¥xÆW²£·~«OÀI¡B
¬y³q¡G ·s¥ú¤T¶V¡B¤T¹´(·L·¼s³õ)¡B«H¸q©Ð«Î¡Bªü¨½¤Ú¤Ú¡B
Æ[¥ú¡G ¤¤«H¶º©±¡B¶³®Ô¶º©±¡B¤Ó¥¬v¡BµØ®õ¡B¤»ºÖ¡B¤Ñ²»´¹µØ¡B¬K¤Ñ°s©±¡B»·¶¯®ü¬v¤½¶é¡B
¹«~¡G ¥xÆWµÒ°s¡B¤Ñ¤¯¯ù¸¡B¤¸¯ª¡B¥ú¬u¡B·sªF¶§¡B¦w¤ß¹«~(¼¯´µº~³ù)¡B®õ¤s¡B®üÅQ¤ý¡B²Î¤@¥ø·~¡B¾ó¤ì±í¡B¯ø´µ¸ª¡B«¢¸ò¹F´µ¦B²N²O¡B
´CÅé¡G ³ü¶Ç´C¡BÁp¦X³ø¡B¥xµø¡BµØµø¡B«D¤Z¹qµø¡B¨È¬w¼s¼½¡B¸ºÐ¼s¼½¡B·¼é°Û¤ù¡B®É³ø©P¥Z¡B
±Ð¨|¡G ¥xÆW¤j¾Ç¡B¥æ³q¤j¾Ç¡B²MµØ¤j¾Ç¡B¤j¦P¤j¾Ç¡B¤¤¥¡¤j¾Ç¡B¤¤ì¤j¾Ç¡B¤¤¿³¤j¾Ç¡B»²¤j¡B°ê»y¹ê¤p¡BÂù¶é°ê¤p¡BµØ¿³¤¤¾Ç¡BªFªù°ê¤p¡B¥x¬ì¤j¡B©ú§Ó¡BªF§d¡BªF®ü¹qºâ¤¤¤ß¡Bªø©°¤j¾Ç¡B«n¨È§Þ³N¾Ç°|¡B¨ÈªF¡B«nªù°ê¤¤¡B¥x®v¤j¡BªFµØ¡B¶§©ú¡B¶³¬ì¤j¡B¦Ë®v¡Bº[«n¤j¾Ç¡B±X¤s¬ì¤j¡B²H¦¿¡B²M¶³¡B³{¥Ò¡B
²Õ´¡G «H«O°òª÷¡B«C³Ð·|¡B¤¤¤p¥ø·~¨ó·|¡BºÞ²z¬ì¾Ç¾Ç·|¡Bì¦í¥Á±Ú¤å¤Æ±Ð¨|¨ó·|¡B¸êµ¦·|¡B¥xºô¤¤¤ß¡B¶³ªù»R¶°
¬F©²¡G ¤¤¬ã°|¡B¤¤¬ì°|¡B°·«O§½¡B¤Ñ¤å¬ì±ÐÀ]¡B¦Á¤îĵ§½¡BªO¾ô¹A·|¡B¥x¥_¿¤®ø¨¾§½¡B°ê½Ã°|¡B®ü¥ÍÀ]¡B°ê¦w§½¡B
ÂåÀø¡G ¥x¤jÂå°|¡B®¦¥D¤½Âå°|¡B¥_¨Ê¦P¤¯°ó¡B®H¨½°ò·þ±ÐÂå°|¡B¸¯Äõ¯À¥v§J¡Bù¤ó¤jÃļt¡B¥Ã«HÃÄ«~¡B
¹q«H¡G ¤j²³¹q«H¡B¥xÆW©Tºô¡B»·¶Ç¹q«H¡B
¥æ³q¡G ¥x¥_±¶¹B¤½¥q¡BµØ¯è¡B¤±]±¶¹B¡B¥xÆW´¼¼z¥d¡B
¤½¯q¡G³ßéw¨à¡B¥ì¨l¡B¶§¥ú°òª÷·|¡B»Z¤½^¡B¿ßÀYÆN
©v±Ð¡G ¤¤¥xÁI¦x¡B°ò·þ±Ð¦æ¹D·|¡B°ò·þ±Ð®û«H·|¡B
x¤è¡G ªÅx¥q¥O³¡¡B°ê¨¾Âå¾Ç°|¡B
|
|
|
|
|
|
|
¡@ |
|